7.4 TEST RESULTS
Line Conducted Emission
Linkou Conduction 4
Job No.:
70125004
Line:
L1
Standard:
CISPR 22 Class B
Test Item:
Conduction Emission
Date:
2006/12/26
Temp.(°C)/Hum.(%RH):
21°C/56%RH
Time:
PM 06:25
Company:
Edimax
Tested By:
Arno Hsieh
Model:
AC-M1000
Test Mode:
Mode 1
NO. Frequency
Quasi
Peak
reading
Average
reading
Correction
factor
Quasi
Peak
result
Average
result
Quasi
Peak
limit
Average
limit
Quasi
Peak
margin
Average
margin
Remark
(MHz) (dBuV) (dBuV) (dB) (dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB) (Pass/Fail)
1 0.17 47.45 36.32 0.20 47.65 36.52 64.96 54.96 -17.31 -18.44 Pass
2 0.68 37.85 25.01 0.10 37.95 25.11 56.00 46.00 -18.05 -20.89 Pass
3 1.20 36.83 23.14 0.12 36.95 23.26 56.00 46.00 -19.05 -22.74 Pass
4 2.33 35.85 19.07 0.22 36.07 19.29 56.00 46.00 -19.93 -26.71 Pass
5 5.63 41.55 40.52 0.45 42.00 40.97 60.00 50.00 -18.00 -9.03 Pass
6 9.09 38.79 21.75 0.78 39.57 22.53 60.00 50.00 -20.43 -27.47 Pass
L1 = Line One (Live Line)