Edimax AC-M1000 Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
Compliance Certification Services Inc.
Report No.: 70125004-D Date of Issue: January 29, 2007
Page 19 Rev. 00
Radiated Emission – Above 1GHz (A)
Model: AC-M1000 Test Mode: Mode 1
Temperature: 26°C
Humidity: 55% RH
Detector Function: Pk/ A.V. Antenna: Vertical at 3m
Tested by: Abol Tsai Test Results: Pass
(The chart below shows the highest readings taken from the final data)
Note: In case of peak reading complied with the limit at least 22dB margin, no measurement with A.V. detector
required.
Freq.
(MHz)
Reading
(dBuV)
Corr.
Factor
(dB/m)
Margin
(dB)
1580.00 47.25 -9.81 37.44 74.00 -36.56
1928.57 44.75 -7.86 36.89 74.00 -37.11
2022.86 46.00 -7.42 38.58 74.00 -35.42
2074.29 46.00 -7.34 38.66 74.00 -35.34
2257.14 45.25 -7.08 38.17 74.00 -35.83
2737.14 45.50 -5.75 39.75 74.00 -34.25
Emiss. Level
(Pk)
(dBuV/m)
Limit 3m
(Pk)
(dBuV/m)