Compliance Certification Services Inc.
Report No.: 70125004-D Date of Issue: January 29, 2007
Page 18 Rev. 00
Radiated Emission (B)
CCS Radiated Test OATS 1
Job No.:
70125004
Ant. Polar.:
Hor.
Standard:
CISPR 22 Class B
Tested Distance:
10m
Test Item:
Radiated Emission
Date:
2006/12/25
Temp.(°C)/Hum.(%RH):
26°C/55%RH
Time:
PM 04:03
Company:
Edimax
Tested By:
Arno Hsieh
Model:
AC-M1000
Test Mode:
Mode 1
No.
Frequency
(MHz)
Reading
(dBuV)
Correction
Factor
(dB/m)
Result
(dBuV/m)
Limit
(dBuV/m)
Margin
(dB)
Degree
(°)
Height
(cm)
Remark
1 133.00 8.10 9.91 18.01 30.00 -11.99 0.00 100.00 QP
2 150.00 16.00 9.64 25.64 30.00 -4.36 0.00 100.00 QP
3 168.00 15.60 10.49 26.09 30.00 -3.91 0.00 100.00 QP
4 188.00 10.20 11.62 21.82 30.00 -8.18 0.00 100.00 QP
5 216.00 15.00 12.92 27.92 30.00 -2.08 0.00 100.00 QP
6 500.00 13.00 20.10 33.10 37.00 -3.90 0.00 100.00 QP